SPP-R210 Command Manual
Rev. 1.00 BIXOLON
- 67 -
GS !
Function:
Select character size
Code:
ASCII
GS
!
n
Hex
1D
21
n
Decimal
29
33
n
Range:
0 ≤ n ≤ 255
(1 ≤ Vertical enlargement ≤ 8, 1 ≤ Horizontal enlargement ≤ 8)
Default:
n=0
Description:
This command selects the character height and width using bits 0 to 3, and bits 4 to 7 respectively as follows:
Bit
Function
Setting
0
Specifies the number of times normal font
size in the vertical direction
Refer to Table 2
[Enlarged in vertical direction]
1
2
3
4
Specifies the number of times normal font
size in the horizontal direction
Refer to Table 1
[Enlarged in horizontal
direction]
5
6
7
Przeglądanie stron 66